Customization: | Available |
---|---|
Type: | Pipe Fittings, Uni-Directional |
Feature: | High Pressure, Long Life and Low Cost |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
China Passage Pig Signaller
China Passage Pig Signallers are used to determine whether a pig has passed or arrived. It is usually placed on the sending and receiving ends of the pig, as well as at key locations on the pipeline. And if you have any other questions, please contact our professionals to answer them for you.
There are three trigger modes to choose from
Bi-directional is Bi-dierctional; code B, can be omitted; 2. Bi-directional feather is Bi-directional Feather, code F; 3. Uni-directional is Uni-directional, code U
EMT's range of Intrusive Ball Indicators are instruments installed on pig transmitter and receiver stations to confirm the launch or arrival of a pig. They can also be installed anywhere on the pipeline and detect the passage of all types of pipeline pigs. Our intrusive ball indicator unit uses a unique magnetic system to prevent fluid exchange from being blocked. So it both eliminates the risk of dynamic seal leakage, increases instrument triggering flexibility, reduces maintenance costs, and is easy to install to on the pipeline. There is interaction between the flag and the trigger mechanism. So the flexibility of the trigger mechanism can be checked online.
Indicator code Item |
B | C | D |
Type | Intrusive | ||
Indicator feature | Manual reset flag | Manual reset flag combined with electrical signals | Date and time display combined with electrical signals |
Installing type | 2″Flange.As per ASME B16.5 (CLASS150~2500) | ||
Plug body length _Correspond to total stand off |
200mm/Meet the actual needs | ||
Operating temperature | -20~120ºC/Meet customer requirements | ||
NACE MR - 01- 75 | Yes | ||
Ingress protection | IP65/IP66 | ||
Explosion-proof class | Exd BT4 | Exd BT4 | |
Remove under pressure | NO |
Indicator code |
B |
C |
D |
Type |
Intrusive China Passage Pig Signaller |
||
Indicator feature |
Manual reset flag |
Manual reset flag combined with electrical signals |
Date and time display combined with electrical signals |
Installing type |
2″Welded base,nipple joint.Design pressure up to 3000Psi |
||
Trigger type |
Uni-directional |
||
Insert depth (In pipe) |
13mm |
||
Plug body length |
settled |
||
Insert depth adjustment |
20mm |
||
Operating temperature |
-20~120ºC/Meet customer requirements |
||
NACE MR - 01- 75 |
Yes |
||
Ingress protection |
IP65/IP66 |
||
Explosion-proof class |
|
Exd BT4 |
Exd BT4 |
Include isolation valve |
NO |
||
With bypass valve |
NO |
||
With bleed valve |
NO |
||
Remove under pressure |
Yes |
||
Retriever |
Special retriever |
China Passage Pig Signaller is the intrusive bidirectional triggering Pig detector. It also used to monitor pig passage. Which can be equipped with multiple displays such as B, C, D, CD display. When the pig passes, the bidirectional trigger into the pipeline triggers each display having the following action:
B: Indication flag turns to vertical from horizontal.
C: Indication flag turns to vertical from horizontal; SPDT or DPDT switch acts and remains active.
D: Digital time display starts counting and memories the actual time when triggered. SPDT or DPDT switch acts and remains till the factory set time, and then display returns to standby.
CD: Indication flag turns to vertical from horizontal. SPDT or DPDT switch acts when the trigger deflects a certain angle and resets after the trigger resets; the digital time display is the same as D.
China Passage Pig Signaller is connected with 2″ flange, were ending with REUV, indicates upper ball valve handled under pressure, i.e. ball valve to be mounted above the foundation; were ending with REDV, indicates lower ball valve handled under pressure, i.e. ball valve to be mounted below the foundation.
Before mounting the Pig detector, the pipe shall be provided and fixed with the flange that conforms to the mounting mode of the said instrument, e.g. the specification, classification, and distribution of mounting holes of the flange shall be in conformity to the standard ANSI B 16.5 or the customized standard. So the space from the flange top face to the internal wall of the pipe shall be 150mm or in conformity to the customized measurement.
Place the sealing gasket compatible with the flange (3.2mm sealing gasket in case of RF flange) between the two flanges to allow the indicator's trigger action direction right against the pipeline. Insert the end with a trigger to the pipeline and fasten the flange seat on the pipeline interface with screws.
When it requires adjusting the direction of B, C, CD display with indication flag. Please slightly loosen four nuts under the square flange of display and turn flag display clockwise to the proper position; after that tighten the loosened four nuts.
When it requires adjusting the direction of the D display, unscrew knurled nut under the display to adjust its direction and then tighten it again.
Brand EMT Pigging
|
Plug Type Bidirectional/Unidirectional
|
Insert Depth 21 mm
|
Flange Material Carbon Steel/Stainless Steel
|
Flange Class 300#
|
Operating Temperature -20 ºC ~ +120 ºC
|
After the long-term operation of oil and gas pipelines, solid pollutants such as paraffin and rust and some liquid and semi-solidified oil pollution may be deposited on the inner wall of the pipeline. This reduces the flow area of the pipe. This also affects pipeline capacity. Moreover, this solid dirt adheres to the inner wall of the pipeline for a long time and may accelerate the corrosion of the pipeline after complex chemical action. They can affect the safety performance of oil and gas pipelines. Therefore, the inner wall of the pipeline must be cleaned regularly.
At present, the commonly used pigging devices mainly include rubber pigging balls, foam pigging devices, leather bowl pigging devices, etc. However, the tools used in pig reception all require professional technicians to operate. If you are a non-professional, it will take a lot of time to learn the instructions and precautions. Moreover, even if the technical essentials are mastered, the problem of signal interference will also occur during use, resulting in the failure of the pig's tracking. Therefore, please read the instruction manual of this product carefully before use.
But sometimes this product will have inaccurate information. Therefore, in addition to installing the ball indicator, the inspectors will also take other means to monitor. For example, they will use various methods to detect, such as listening on cathodic protection piles, sitting on the ground and feeling the vibration of pipelines. These methods can ensure the accuracy of detection. And usually they will set multiple detection points a few kilometers before and after the instrument.
In this way, it can ensure that the inspectors can clearly know the location of the pig. After the pig successfully reaches the pig receiver, the inspector can recover the sewage and take out the pig. They can also take samples, measure pig data, recover processes, etc. So, the pigging operation of a trunk line can be successfully completed. Through pigging operation, we can remove the accumulated liquid in the pipeline and improve the efficiency of pipeline transportation. All these can lay a good foundation for ensuring production in winter and gas supply in peak periods.